Stair Rise and Run Calculator
Your floor-to-floor height split into risers: every sensible count side by side…
Your floor-to-floor height split into risers: every sensible count side by side, plotted against the building code’s limits and the rule of thumb for a comfortable step.
finished floor to finished floor · 7 ft 10 in
Tread run
Risers
13 is the fewest that keep each riser at 7¾ in or less; more risers make a gentler stair that takes more floor.
More optionsIRC 2021
Check against
ExampleEach step
7¼ inrise × 11 in run
13 risers of 7¼ in and 12 treads of 11 in: 11 ft of floor at 33.3°.
Enter yours to see your result.
- Twice the rise plus the run
- 25 7/16 in
- Floor it takes
- 11 ft
An estimate of materials to buy, not engineering or code advice. Check sizes with your supplier and local building department. Terms
Code check · informational
- Riser height (within the limit)7¾ in at most; keep every riser within ⅜ in of the others. R311.7.5.17¼ in
- Tread depth, nosing to nosing (within the limit)10 in at least. R311.7.5.211 in
- Nosing (within the limit)Not needed on treads of 11 in or more; 1¼ in at most. R311.7.5.30 in
- Rise of one flight (within the limit)12 ft 7 in at most between floors or landings. R311.7.37 ft 10 in
- Width (within the limit)36 in clear at least, above the handrail. R311.7.136 in
- Handrail on at least one sideWith 13 risers (4 or more): 34 in to 38 in above the nosings. R311.7.8, R311.7.8.1
The 2021 International Residential Code, R311.7 and R312.1, as printed in the SMA’s visual interpretation. Informational: your town may adopt another edition or amend it, and its inspector decides.
How this works: 4 sources,
How this works
Method
The total rise is fixed by the building, so the only free choice is how many pieces to cut it into. Each count gives a riser height (total rise ÷ risers) and, with the tread run you pick, the stair’s length on the floor (treads × run, one tread fewer than risers). The chart plots every sensible count for your rise against the building code’s box, risers at most 7¾ in and treads at least 10 in under the IRC, so you can see at a glance which ones are legal and how much floor each takes. Full method
Sources
- Approved Document K: Protection from falling, collision and impact, 2013 edition (Table 1.1, paras 1.11, 1.34, 1.41) (HM Government (England), 2013)
- 2021 International Residential Code, R311.7 Stairways and R312.1 Guards (text as printed in the SMA Visual Interpretation of the 2021 IRC Stairbuilding Codes, 2023) (International Code Council; Stairway Manufacturers’ Association, 2023)
- DCA 6, Prescriptive Residential Wood Deck Construction Guide (stair requirements and commentary) (American Wood Council, 2018)
- Voluntary Product Standard PS 20-25, American Softwood Lumber Standard (dressed sizes, standard lengths) (National Institute of Standards and Technology, 2025)
How it’s tested
2 worked examples for this page are checked by automated tests before every release: given the inputs, the tool must show the expected answer.
Limits
An estimate of materials to buy, not engineering or code advice. Check sizes with your supplier and local building department.
Privacy
On your device. Nothing you enter or open leaves this browser. About privacy labels
Changes
- First published: a staircase drawn to scale from its total rise, with the stringer layout, rise and run, deck stairs, stairs with a landing and the IRC and Approved Document K limits checked.
How the rise and run are chosen
The total rise is fixed by the building, so the only free choice is how many pieces to cut it into. Each count gives a riser height (total rise ÷ risers) and, with the tread run you pick, the stair’s length on the floor (treads × run, one tread fewer than risers). The chart plots every sensible count for your rise against the building code’s box, risers at most 7¾ in and treads at least 10 in under the IRC, so you can see at a glance which ones are legal and how much floor each takes.
For 112 in floor to floor at a 10½ in run: 112 ÷ 7.75 = 14.45, so the fewest is 15 risers of 7 7/16 in, 12 ft 3 in of run at 35.4°. One more riser, 16 of 7 in, is gentler and takes 13 ft 1½ in. Both pass; the second is easier on the knees if you have the floor for it.
The dashed band is a long-standing rule of thumb for a comfortable step: twice the rise plus the run (2R + G) between 550 and 700 mm, about 21⅝ to 27½ in. England’s Approved Document K writes it into its guidance; the IRC doesn’t, but its own limits sit inside the band. A stair near the middle of it, around 25 in, feels natural to most people.
riser = total rise ÷ n; treads = n − 1; run on the floor = (n − 1) × tread run; angle = atan(riser ÷ run)
- Approved Document K gives the normal relationship between rise and going as twice the rise plus the going between 550 mm and 700 mm, with a private stair’s rise 150 to 220 mm, going 220 to 300 mm and pitch at most 42°. Source: Approved Document K: Protection from falling, collision and impact, 2013 edition (Table 1.1, paras 1.11, 1.34, 1.41).
- A nosing of ¾ to 1¼ in is required on treads under 11 in deep; at 11 in or more it is not (IRC R311.7.5.3). Source: 2021 International Residential Code, R311.7 Stairways and R312.1 Guards (text as printed in the SMA Visual Interpretation of the 2021 IRC Stairbuilding Codes, 2023).
Without a calculator
Divide the total rise by 7 for a comfortable count and by 7.75 for the least, round both up, and pick between them. For 94 in, 94 ÷ 7.75 = 12.1 → 13 risers of 7¼ in; 94 ÷ 7 = 13.4 → 14 risers of 6 11/16 in.
Risers for common floor-to-floor heights
The fewest risers under 7¾ in, the run at a 10 in tread and the angle, and the next count up.
| Total rise | Fewest risers | Run | Angle | One more |
|---|---|---|---|---|
| 7 ft | 11 × 7⅝ in | 8 ft 4 in | 37.4° | 12 × 7 in |
| 7 ft 6 in | 12 × 7½ in | 9 ft 2 in | 36.9° | 13 × 6 15/16 in |
| 8 ft | 13 × 7⅜ in | 10 ft | 36.4° | 14 × 6⅞ in |
| 8 ft 4 in | 13 × 7 11/16 in | 10 ft | 37.6° | 14 × 7⅛ in |
| 8 ft 9 in | 14 × 7½ in | 10 ft 10 in | 36.9° | 15 × 7 in |
| 9 ft | 14 × 7 11/16 in | 10 ft 10 in | 37.6° | 15 × 7 3/16 in |
| 9 ft 4 in | 15 × 7 7/16 in | 11 ft 8 in | 36.7° | 16 × 7 in |
| 10 ft | 16 × 7½ in | 12 ft 6 in | 36.9° | 17 × 7 1/16 in |
Sources
- HM Government (England), Approved Document K: Protection from falling, collision and impact, 2013 edition (Table 1.1, paras 1.11, 1.34, 1.41)
- International Code Council; Stairway Manufacturers’ Association, 2021 International Residential Code, R311.7 Stairways and R312.1 Guards (text as printed in the SMA Visual Interpretation of the 2021 IRC Stairbuilding Codes, 2023)
The codes are cited for their limits as published; the check on this page is informational, and the code your town adopts, with its amendments, is the one that applies.
Common questions
What is a good rise and run for stairs?
Something like a 7 to 7½ in riser with a 10½ to 11 in tread: legal under the IRC and close to the comfortable 2R + G of about 25 in. Steeper stairs save floor; shallower ones are easier to climb.
How many steps for an 8 ft ceiling?
With an 8 ft ceiling and a typical floor structure the floor-to-floor height is about 105 to 108 in, which takes 14 risers of 7½ to just under 7¾ in under the IRC, and 13 treads.
What is the maximum stair angle?
The IRC has no angle limit, but 7¾ in risers on 10 in treads come to about 37.8°. Approved Document K caps a private stair at 42°.
Do I count the top floor as a step?
Yes. The upper floor is the last tread, so a stair has one tread fewer than risers. Fourteen risers means thirteen treads to cut.