Your floor-to-floor height split into risers: every sensible count side by side…

Your floor-to-floor height split into risers: every sensible count side by side, plotted against the building code’s limits and the rule of thumb for a comfortable step.

in

finished floor to finished floor · 7 ft 10 in

Tread run

in

Risers

13 is the fewest that keep each riser at 7¾ in or less; more risers make a gentler stair that takes more floor.

More optionsIRC 2021
in
in

Check against

ExampleEach step

7¼ inrise × 11 in run

13 risers of 7¼ in and 12 treads of 11 in: 11 ft of floor at 33.3°.

Enter yours to see your result.

891011121356789Tread run (in) →Riser (in) →IRC 20212R + G comfort band12 × 7 13/16 in13 × 7¼ in14 × 6 11/16 in15 × 6¼ in16 × 5⅞ in
Riser against run: the shaded box is the IRC’s 7¾ in riser and 10 in tread, the dashed band twice the rise plus the run between 21⅝ in and 27 9/16 in. Tap a count to pick it.
Twice the rise plus the run
25 7/16 in
Floor it takes
11 ft

An estimate of materials to buy, not engineering or code advice. Check sizes with your supplier and local building department. Terms

Code check · informational

  • Riser height (within the limit)7¾ in at most; keep every riser within ⅜ in of the others. R311.7.5.17¼ in
  • Tread depth, nosing to nosing (within the limit)10 in at least. R311.7.5.211 in
  • Nosing (within the limit)Not needed on treads of 11 in or more; 1¼ in at most. R311.7.5.30 in
  • Rise of one flight (within the limit)12 ft 7 in at most between floors or landings. R311.7.37 ft 10 in
  • Width (within the limit)36 in clear at least, above the handrail. R311.7.136 in
  • Handrail on at least one sideWith 13 risers (4 or more): 34 in to 38 in above the nosings. R311.7.8, R311.7.8.1

The 2021 International Residential Code, R311.7 and R312.1, as printed in the SMA’s visual interpretation. Informational: your town may adopt another edition or amend it, and its inspector decides.

How this works: 4 sources,

How this works

Method

The total rise is fixed by the building, so the only free choice is how many pieces to cut it into. Each count gives a riser height (total rise ÷ risers) and, with the tread run you pick, the stair’s length on the floor (treads × run, one tread fewer than risers). The chart plots every sensible count for your rise against the building code’s box, risers at most 7¾ in and treads at least 10 in under the IRC, so you can see at a glance which ones are legal and how much floor each takes. Full method

How it’s tested

2 worked examples for this page are checked by automated tests before every release: given the inputs, the tool must show the expected answer.

Limits

An estimate of materials to buy, not engineering or code advice. Check sizes with your supplier and local building department.

Privacy

On your device. Nothing you enter or open leaves this browser. About privacy labels

Changes

  • First published: a staircase drawn to scale from its total rise, with the stringer layout, rise and run, deck stairs, stairs with a landing and the IRC and Approved Document K limits checked.

Every change on What’s new

How we make toolsReport a mistake

How the rise and run are chosen

The total rise is fixed by the building, so the only free choice is how many pieces to cut it into. Each count gives a riser height (total rise ÷ risers) and, with the tread run you pick, the stair’s length on the floor (treads × run, one tread fewer than risers). The chart plots every sensible count for your rise against the building code’s box, risers at most 7¾ in and treads at least 10 in under the IRC, so you can see at a glance which ones are legal and how much floor each takes.

For 112 in floor to floor at a 10½ in run: 112 ÷ 7.75 = 14.45, so the fewest is 15 risers of 7 7/16 in, 12 ft 3 in of run at 35.4°. One more riser, 16 of 7 in, is gentler and takes 13 ft 1½ in. Both pass; the second is easier on the knees if you have the floor for it.

The dashed band is a long-standing rule of thumb for a comfortable step: twice the rise plus the run (2R + G) between 550 and 700 mm, about 21⅝ to 27½ in. England’s Approved Document K writes it into its guidance; the IRC doesn’t, but its own limits sit inside the band. A stair near the middle of it, around 25 in, feels natural to most people.

riser = total rise ÷ n; treads = n − 1; run on the floor = (n − 1) × tread run; angle = atan(riser ÷ run)

Without a calculator

Divide the total rise by 7 for a comfortable count and by 7.75 for the least, round both up, and pick between them. For 94 in, 94 ÷ 7.75 = 12.1 → 13 risers of 7¼ in; 94 ÷ 7 = 13.4 → 14 risers of 6 11/16 in.

Risers for common floor-to-floor heights

The fewest risers under 7¾ in, the run at a 10 in tread and the angle, and the next count up.

The fewest risers under 7¾ in, the run at a 10 in tread and the angle, and the next count up.
Total riseFewest risersRunAngleOne more
7 ft11 × 7⅝ in8 ft 4 in37.4°12 × 7 in
7 ft 6 in12 × 7½ in9 ft 2 in36.9°13 × 6 15/16 in
8 ft13 × 7⅜ in10 ft36.4°14 × 6⅞ in
8 ft 4 in13 × 7 11/16 in10 ft37.6°14 × 7⅛ in
8 ft 9 in14 × 7½ in10 ft 10 in36.9°15 × 7 in
9 ft14 × 7 11/16 in10 ft 10 in37.6°15 × 7 3/16 in
9 ft 4 in15 × 7 7/16 in11 ft 8 in36.7°16 × 7 in
10 ft16 × 7½ in12 ft 6 in36.9°17 × 7 1/16 in

Common questions

What is a good rise and run for stairs?

Something like a 7 to 7½ in riser with a 10½ to 11 in tread: legal under the IRC and close to the comfortable 2R + G of about 25 in. Steeper stairs save floor; shallower ones are easier to climb.

How many steps for an 8 ft ceiling?

With an 8 ft ceiling and a typical floor structure the floor-to-floor height is about 105 to 108 in, which takes 14 risers of 7½ to just under 7¾ in under the IRC, and 13 treads.

What is the maximum stair angle?