Dilution Calculator (C1V1 = C2V2)
Type three of the four values to get the fourth: how much stock solution to measure…
Type three of the four values to get the fourth: how much stock solution to measure, how much solvent to add and what concentration you end up with.
Concentration in
Each value can have its own unit, such as a 1 M stock diluted to 50 mM, or 20 µL made up to 50 mL.
ExampleFinal volume
400mL
Measure 50.0 mL of the 2.00 M stock and make it up to 400 mL with solvent (about 350 mL) for 0.250 M.
Type your own concentrations and volumes.
- Solvent to add, about
- 350 mL
- Dilution factor
- 8.00×
- Stock share
- 1 part in 8.00
How this works: 4 sources,
How this works
Method
Diluting adds solvent and nothing else, so the amount of solute stays the same before and after. Amount is concentration times volume, which gives C1V1 = C2V2: the stock’s concentration and the volume you take of it on one side, the diluted solution’s concentration and total volume on the other. Any one of the four can be found from the other three. Full method
Sources
How it’s tested
2 worked examples for this page are checked by automated tests before every release: given the inputs, the tool must show the expected answer.
Privacy
On your device. Nothing you enter or open leaves this browser. About privacy labels
Changes
- First published: molarity with a recipe, dilution with a drawing of the two vessels, mass percent, ppm against drinking water limits, and pH solved exactly for strong and weak acids and bases.
How to use C1V1 = C2V2
Diluting adds solvent and nothing else, so the amount of solute stays the same before and after. Amount is concentration times volume, which gives C1V1 = C2V2: the stock’s concentration and the volume you take of it on one side, the diluted solution’s concentration and total volume on the other. Any one of the four can be found from the other three.
To make 400 mL of 0.250 M solution from a 2.00 M stock, V1 = C2V2 ÷ C1 = 0.250 × 400 ÷ 2.00 = 50.0 mL. Measure 50.0 mL of stock into a 400 mL volumetric flask and add water to the mark, which is 350 mL more. The dilution factor, V2 ÷ V1, is 8: the final solution is one eighth as strong.
Units only need to match on each side. Both concentrations can be in molarity, mass per volume (% w/v or mg/mL) or a buffer’s “X” strength, and both volumes in mL or L, because the units cancel. For acids, add acid to water rather than water to acid, since the heat released can make the first drops of water boil and spatter.
C1 × V1 = C2 × V2
- When a solution is diluted the moles of solute are unchanged, so the product of concentration and volume is the same before and after. Source: OpenStax Chemistry 2e, 3.3 Molarity (dilution of solutions).
Stock needed for common dilutions
The volume of stock to measure and of water to add, from C1V1 = C2V2.
| Stock C1 | Wanted C2 | Final V2 | Stock V1 | Water to add |
|---|---|---|---|---|
| 12.0 M | 1.00 M | 500 mL | 41.7 mL | 458 mL |
| 12.0 M | 0.100 M | 1000 mL | 8.33 mL | 992 mL |
| 6.00 M | 1.00 M | 250 mL | 41.7 mL | 208 mL |
| 2.00 M | 0.250 M | 400 mL | 50.0 mL | 350 mL |
| 1.00 M | 0.0100 M | 100 mL | 1.00 mL | 99.0 mL |
| 10X | 1X | 1000 mL | 100 mL | 900 mL |
| 50X | 1X | 500 mL | 10.0 mL | 490 mL |
| 20 % w/v | 2 % w/v | 1000 mL | 100 mL | 900 mL |
| 70 % v/v | 10 % v/v | 100 mL | 14.3 mL | 85.7 mL |
| 1000 mg/mL | 5 mg/mL | 200 mL | 1.00 mL | 199 mL |
Common questions
Is it C1V1 = C2V2 or M1V1 = M2V2?
They are the same equation. M1V1 = M2V2 uses molarity for the concentrations; C1V1 = C2V2 works with any concentration unit, as long as both sides use the same one.
Do I add V2 of water?
No. V2 is the final total volume. You add V2 − V1 of solvent, or more precisely you fill to the V2 mark, because mixed volumes don’t always add exactly.
How do I do a serial dilution?
Repeat the same dilution several times, each time taking the last solution as the new stock. Five 1 in 10 steps give a 1 in 100,000 dilution, which is more accurate than measuring one tiny volume.
Can the final concentration be higher than the stock?
Not by adding solvent. If C2 comes out larger than C1, two values were swapped; the tool says so instead of giving a number.